二维搜索
Sketch the part you are looking for or have a photo described in text form
Create image description with AI
Create image description with AI
Drop file here
支持的文件格式: .PNG, .JPG, .JPEG, .WEBP
1/5
1
1
2|0
3
4
4
0
0
0
0
0
0
0
0
0
0

283292

Expand Table
所有配送国家/地区
EN
1/5
Preview
PREVIEW
PLID
Manufacturer Type Description
MANUTYPEDESC
Short Description
DESCSHORT
Long Description
DESCLONG
International product number
INTNO
Netto weight
NETTO_WEIGHT [kg]
ECLASS-13.0
ECLASS_13_0
ETIM-10.0
ETIM_10_0
Suitable for number of poles [EF001589]
EF001589
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
281591
NZM4-XKV95
Connection width extension, 3p, spacing 95mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for: NZM4, N(S)4
4015082815912
3.17500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
266821
NZM4-4-XKM2
Module plate 2-hole 4p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4-4, N4-4
4015082668211
0.82500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
132673
NZM3-4-XKV70-2
Connection width extension, 4p, 2-hole
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 pole circuit-breakers. Double hole fitting for up to 4 185 mm² cable lugs, 50mm busbar or large flat cable terminal NZM4-XKB or large tunnel terminal NZM4-XKA. Can be fitted to circuit-breaker with screw connection. Phase isolator, insulation plate and 2 control circuit terminals included as standard. Can be used for: NZM3(-4), PN3(-4), NS3(-4)
4015081296118
0.82000
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
284474
NZM4-4-XKM2S-1600
Module plate, 2-hole, vertical, 4p, 1600A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for NZM4-4, N4-4
4015082844745
3.24200
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
285610
N4-XAS12-1250
N4/N12 adapter set 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
4015082856106
2.03300
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
284472
NZM4-4-XKM2S-1250
Module plate, 2-hole, vertical, 4p, 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for NZM4-4, N4-4
4015082844721
1.94200
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
132674
NZM4-4-XKV95-2KB
Connection width extension, 4p, 2 studs
Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple.
4015081296125
4.70000
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
285611
N4-XAS12-1600
N4/N12 adapter set 1600A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
4015082856113
3.59500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
285614
NZM4-XAS12-1600
Adapter set, 1600A, NZM4/NZM12
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: NZM4
4015082856144
5.12500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
266815
NZM4-4-XKM1
Module plate 1-hole 4p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4-4, N4-4
4015082668150
0.82500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
283292
NZM4-XAS14-1600
Adapter set, 1600A, NZM4/NZM14
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch. 3 connection extensions on outlet side. 3 connection extensions on trip block side. 1 long shroud for the outlet side. paper drilling template in the assembly and maintenance instructions . Cannot be combined with module plate (NZM4-XKM..), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV..), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV..). Can be used for: NZM4, N4
4015082832926
7.44000
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
266820
NZM4-XKM2
Module plate 2-hole 3p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
4015082668204
0.63900
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
119860
NZM3-XKV70-2
Connection width extension, 3p, 2-hole, size 3
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 pole circuit-breakers. Double hole fitting for up to 4 185 mm² cable lugs, 50mm busbar or large flat cable terminal NZM4-XKB or large tunnel terminal NZM4-XKA. Can be fitted to circuit-breaker with screw connection. Phase isolator, insulation plate and 2 control circuit terminals included as standard. Can be used for: NZM3, PN3, N(S)3
4015081177110
0.61000
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
284471
NZM4-XKM2S-1250
Module plate, 2-hole, vertical, 3p, 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
4015082844714
1.43200
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
109060
PN/N3-4-XKV70-SK
Connection width extension, 4p, short
Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple.
4015081086801
0.88000
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
285609
N4-XAS12-1000
N4/N12 adapter set 800A/1000A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
4015082856090
1.90300
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
281594
NZM4-4-XKV120
Connection width extension, 4p, spacing 110mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for NZM4-4, N4-4
4015082815943
5.03500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
266814
NZM4-XKM1
Module plate 1-hole 3p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
4015082668143
0.62100
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
3
281592
NZM4-4-XKV95
Connection width extension, 4p, spacing 95mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for NZM4-4, N4-4
4015082815929
4.27500
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
4
显示压缩表示形式 (27 Produkt)