Connection width extension, 3p, spacing 95mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for: NZM4, N(S)4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate 2-hole 4p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 4p, 2-hole
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 pole circuit-breakers. Double hole fitting for up to 4 185 mm² cable lugs, 50mm busbar or large flat cable terminal NZM4-XKB or large tunnel terminal NZM4-XKA. Can be fitted to circuit-breaker with screw connection. Phase isolator, insulation plate and 2 control circuit terminals included as standard. Can be used for: NZM3(-4), PN3(-4), NS3(-4)
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate, 2-hole, vertical, 4p, 1600A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate, 2-hole, vertical, 4p, 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 4p, 2 studs
Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple.
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Adapter set, 1600A, NZM4/NZM12
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: NZM4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate 1-hole 4p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Adapter set, 1600A, NZM4/NZM14
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch. 3 connection extensions on outlet side. 3 connection extensions on trip block side. 1 long shroud for the outlet side. paper drilling template in the assembly and maintenance instructions . Cannot be combined with module plate (NZM4-XKM..), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV..), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV..). Can be used for: NZM4, N4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate 2-hole 3p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 3p, 2-hole, size 3
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 pole circuit-breakers. Double hole fitting for up to 4 185 mm² cable lugs, 50mm busbar or large flat cable terminal NZM4-XKB or large tunnel terminal NZM4-XKA. Can be fitted to circuit-breaker with screw connection. Phase isolator, insulation plate and 2 control circuit terminals included as standard. Can be used for: NZM3, PN3, N(S)3
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate, 2-hole, vertical, 3p, 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 4p, short
Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple.
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
N4/N12 adapter set 800A/1000A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from N(ZM)12 to N(ZM)4. With the terminal lugs of the replacement kit all 3 pole NZM12 and N12 can be adapted to the connection dimensions of the NZM4 or N4 manufactured from model year 1983. 4 pole basic devices, withdrawable units and basic devices with remote operator can not be replaced . Contents of replacement kits of N(ZM)4-XAS12.., 3 connection extensions on outlet side, 3 connection extensions on trip block side, 2 mounting brackets, 4 fixing screw, 4 phase isolators, 6 fixing screw, nuts and strain washers. Paper drilling template in the assembly and maintenance instructions. The replacement kits have the same dimensions as models N(ZM)12…, which correspond to production status 02/97 to the present. Special features: prior to 12/800 the N(ZM)02-97 was supplied with 10 mm instead of 8 mm terminal lugs . With these models the customer must determine the device’s year of manufacture by measuring the thickness of the terminal lug and order replacement kit N(ZM)4-XAS12-1250. Addition for devices constructed prior to 1983! here the replacement kit for switch-disconnectors can be used in full. For circuit-breakers with “long” ZM design, the adapter fit only at the top! At the bottom the devices are about 65 mm longer and the lower connection is about 26 mm deeper. Consequently the bottom adapters are too short and the heights do not correspond. Can be used for: N4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 4p, spacing 110mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Module plate 1-hole 3p, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]
Connection width extension, 4p, spacing 95mm
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. Five-hole fitting, for example for up to 9 cable lugs per phase. Can be fitted to circuit-breaker with screw connection. Phase isolator included as standard. distance between pole centers NZM4(-4)-XKV95: 95 mm installation conditions for current transformer up to 130 mm width with 80 mm busbar width . Distance between pole centers NZM4-XKV110: 107.5 mm installation conditions for current transformer up to 135 mm width with 80 mm busbar width. Distance between pole centers NZM4-4-XKV120: 122 mm installation conditions for current transformer up to 164 mm width with 80 mm busbar width. 4 mm holes predrilled for control circuit terminal. NZM4-XKV95 contains hole for large cover NZM4‑XKSAV. Can be used for NZM4-4, N4-4
Connection vane/phase spreader [ACN990017]
Connection vane/phase spreader [EC002019]